This calculator is designed to give an estimate of the heating needs of a room or a combination of rooms.

Use our BTU Calculator

Order Parts

IX410

400,000 BTU/HR - High Capacity, Indirect Fired Heater
Features: 
  • 4 Safety shutdown controls
  1. High limit switch
  2. Exhaust limit switch
  3. Air switch
  4. Flame Rod
  • Quick Change fuel Supply
  1. Dual fuel selector valve for propane & natural gas (no orifice to change)
  • High efficiency Stainless Steel heat exchanger (SS403)
  • Durable exoskeleton
  1. increased structural integrity and more efficient air flow
  2. Quick and easy stack ability for off season storage
  • 16” Puncture proof wheels - For easy maneuverability
  • Lifting hook & fork lift pockets
  • Powder coated shell for high impact resistance
  • Operate on 12 Amps
  • Not polarity sensitive
  1. reduced costly service calls
  • Ductable
  1. One 16” duct
  2. Two 12” duct (optional)
  3. One 18” duct (optional)
  • 16” Recirculation duct attachment feature Accessible burner and controls
  1. Easy access doors
BTU Rating: 
400,000 BTU/HR

Stackable - Quick easy stack ability for off season storage

Single stage external thermostat (optional)

Recirculation Feature

Duct adaptor options - two 12" duct adaptor (optional) one 18" duct adaptor (optional)

 

Heat Capacity

400,000BTU

Fuel Consumption NG/P

400 CFH / 18.5lbs/h

Power Requirements

115V/60Hz/ 1PH/12A

Heat Exchanger

20ga SS304

Combustion Chamber 

18ga SS304

Dimensions (LxWxH)

82"X29"X58.5"

Net Weight

560lbs

Temperature Rise(w/o duct)

90°C 

Temperature Rise(with duct)

100°C 

Max Heated Air Flow (w/o duct)

2750CFM

Air Outlet (Optional)

 One 16"/One 18"/Two 12"

Air Inlet

Ductable 16"

Efficiency

90%

Fan Rating

5000 CFM@2.65"

Finish

Powder Coated

Ignition

Direct Spark

Wheels

Two 16" Dia Puncture Proof